Stay Warm With Separated Combustion Unit Heaters

Don’t miss the new line of separated combustion unit heaters from Detroit Radiant Products Company! They are a compact, aesthetically pleasing commercial heater that has aluminized steel heat exchanges and finger-proof fan guards.

 

FA Series heater

FA Series Features:

– BTU range of 100,000 to 250,000.
– Traditional profile design with durable, powder-coated black enamel.
– Aluminized steel tubular heat exchangers.
– Stainless steel discharge louvers.
– Swept wing air propeller, for noise reduction.
– Finger proof fan guards are standard.
– External operational indicator lights are standard.
– External thermostatic connection.
– 100 MBH and 125 MBH models can be rotated 180°.
– Approved separated combustion can be field converted to power vented without additional parts or cost.

 

UH Series heater

UH Series Features:

– BTU range of 30,000 to 75,000.
– Low profile design with durable, powder-coated black enamel.
– Aluminized steel tubular heat exchangers.
– Individual in-shot burners.
– Stainless steel discharge louvers.
– Finger proof fan guards are standard.
– External operational indicator lights are standard.
– External thermostatic connection.
– Integrated mounting brackets accommodate joists on 16 or 24″ O.C.
– 180º mounting.
– Approved separated combustion can be field converted to power vented without additional parts or cost.

Keep Your Building Warm With The SW Series Heater

infrared_heater_climate_systems
Don’t miss this new product from Detroit Radiant Products Company! The SW Series short wave electric infrared heater is unique in its’ ability to produce both infrared heat and visible light energy.

Benefit from the highly efficient energy transfer, lower mounting heights, heat energy, light energy, and certification for both indoor or outdoor use.
Product Features Include:

  • Single, double or triple construction models.
  • 1 to 3 Elements: Choose either clear quartz lamps or optional glare reducing ruby quartz lamps.
  • Compact, aesthetically pleasing construction. Heater housing available in either black powder coated aluminized steel or brushed 304 grade stainless steel.
  • 0° to 45° adjustable mounting brackets included.
  • Lower Clearances.

Click here to learn more about the SW Series Short Wave Electric Infrared Heater!

Click here to like us on Facebook!

ASHRAE Standards

ashrae

As Variable Refrigerant Flow (VRF) systems are applied to more buildings in the United
States, many designers have asked for recommendations to apply VRF systems in compliance
with ASHRAE Standards 15 & 34.

ASHRAE Standards 15 & 34 are refrigerant safety standards recognized by many state and
local building codes. Local codes may vary from ASHRAE Standards 15 & 34 and it is
recommended that the designer review these local codes for differences from ASHRAE
Standards 15 & 34.

Frequently Asked Questions:

Q: I thought ASHRAE Standards 15 & 34 only apply to chiller systems. Do VRF systems need
to comply with ASHRAE Standards 15 & 34?
A: Chiller systems were popular when ASHRAE Standard 15 was originally introduced in 1930.
However, ASHRAE Standard 15 applies to all air conditioning systems that use refrigerant including VRF systems, packaged rooftop units, split systems, and chiller systems

Q: Can the ceiling space (plenum) be calculated as part of the occupied volume?
A: According to ASHRAE 15: “The space above a suspended ceiling shall not be included in
calculating the refrigerant quantity limit in the system unless such space is part of the air
supply or return system”

Q: When using a ducted indoor unit serving multiple offices, what volume is used for
occupied volume?
A: Multiple offices connected by ductwork can combine the volume of the offices in the
occupied volume calculation.

Q: Where can I find the total system charge for the VRF system?
A: The LATS selection software generates an output report shows the product charge and
Additional Ref. Amount. These (2) values can be added to obtain the total system refrigerant
charge.

Q: What size should the permanent opening be to connect occupied spaces?
A: The size of a permanent opening is not listed in ASHRAE 15 and is subject to engineering
judgment. Locating the permanent opening low on the wall is recommended since R410A
refrigerant is heavier than air. It is also recommended that you consult with your local code
authority.

Learn more about ASHRAE Standards here!

More resources about ASHRAE!

Click here to visit the LG website!

Kelley Fans

Kelley Entrematic - Logo

Kelley engineers build solutions through innovative products, and they’ve followed suit with the Kelley WAVE. This fan is advancing HVLS technology through controls, improved airflow and energy saving.

Benefits:

1. Keeps employees cool and comfortable

2. Reduces energy consumption

3. Protect product integrity

4. Improves general working conditions

5. Contributes to LEED certification credits in various categories

Like us on Facebook!

Read more about Kelley Fans!